Specifications
DIGITAL MULTIMETER 
  OPERATING INSTRUCTION
3 The meter will enter the manual range mode after the 
“REL” button is pressed.    REL mode is not available 
for Hz/Duty range because it is an automatic range. 
4) Press  the  “REL”  button  again  to  cancel  the  relative 
measurement function. 
5 Pressing  the “REL”  button at  the HOLD  mode will 
cancel the HOLD function.   The actual measurement 
value taken will be stored in the memory as reference 
value.    The  readings  displayed  for  measurements 
taken  afterwards  will  be the  difference  between  the 
input value and the reference value. 
6 Press the “RANGE”, “SELECT” buttons or turning the 
rotary  selector  to  cancel the  relative  measurement 
function and resume normal measurement.   The REL 
symbol on the display will disappear.   
7 OL triggering: Under the REL mode, OL (over limit) will 
flash on the  display if  the input value exceeds the 
allowed value for that range.   Press the “REL” button 
again to cancel the  relative measurement function.   
The REL mode cannot be entered when OL is flashing.   
4.7 BACK LIGHT 
1  Press the ”HOLD/B.L” button for two or more seconds 
to  switch  on  the  back  light  if  the  light  in  the 
environment is too dim for taking reading,. 
2 Press the “HOLD/B.L” button for two or more seconds   
- 26 - 
DIGITAL MULTIMETER 
  OPERATING INSTRUCTION
again to switch off the back light. 
3 The  back  light  will  go  off  automatically  after  10 
seconds. 
NOTE: 
1)  LED, which  requires  a  larger working  current,  is the 
main source of  back light.  Although the meter is 
equipped with a timer set at 10 seconds (i.e. the back 
light  will  be  off  automatically  after  10  seconds), 
frequent use of the back light will shorten the life of the 
batteries.    Therefore, do not use the back light unless 
necessary. 
2) When the battery voltage is ≤3.6V, the symbol “ ”
battery  low will appear  on  the LCD.   When  the 
back light is on, even if the batter is ≥3.6V, the “ ” 
may appear because of its large working current which 
will cause the voltage to drop.   (The accuracy of the 
measurement  cannot  be  assured  when  the 
“ “  symbol  appears.)    In  this  case, you  need  not 
replace the batteries yet.   Normally, the batteries can 
last until the “ ” appears when the back light is not 
being used. 
4.8 AUTO POWER OFF 
1 If  there  is  no  any  operation  within  any thirty minute 
period after the power is on, the meter will enter the 
auto power off mode. 
- 27 - 