Specifications
DIGITAL MULTIMETER 
  SPECIFICATION
 NTS
3.2.4 AC Current 
Range  Resolution
Accuracy 
400µA  0.1µA   
4000µ A
1µA   
40mA  10µ A  ± 1.5% of reading + 5 digits
400mA  100µA   
4A  1mA   
10A  10mA  ± 3.0% of reading + 10 digits
- Overload protection:   
µA mA ranges: resettable fuses F1    500mA/250V 
10A range: F2   10A/250V fuse (quick acting),. 
- Max. input current:   
mA jack µA ranges : 4mA,   
mA jack mA ranges : 400mA, 
10A jack: 10A 
- voltage drop  
400µA ranges: 40mV, 
4000µA ranges: 400mV, 
40mA ranges: 40mV, 
400mA ranges: 400mV, 
4A range: 40mV 
10A range: 100mV 
- Frequency range: 40 to 400Hz   
- Response: average, calibrated in rms of sine wave 
- 16 - 
DIGITAL MULTIMETER 
  SPECIFICATION
 NTS
3.2.5 Resistance 
Range  Resolution  Accuracy 
400Ω  0.1Ω 
4kΩ  1Ω 
40kΩ  10Ω 
400k(  100Ω 
4M(  1kΩ 
±(1.2% of reading + 2 digits) 
40M(  10kΩ  ± (2.0% of reading + 5 digits)
- Open circuit voltage: ~0.25V 
- Overload protection: 250V DC or rms AC 
3.2.6 Capacitance 
Range  Resolution  Accuracy 
40nF  10pF   
400nF  0.1nF   
4µF  1nF  ± 3.0% of reading + 3 digits
40µF  10nF   
100µF  100nF   
- Overload protection: 250V DC or rms AC 
- 17 - 