Specifications

35
2. After assuring that the power is turned off and locked out, and the tank has
been drained and given a chance to cool, unlock and open the door to the
electric control cabinet.
Note: Figure 1 illustrates the typical EHB type heating element and mounting.
3. Disconnect the electrical connections at the terminals of the heating
element to be replaced. It is suggested that the wires be tagged to assure
correct reconnection.
4. Using 9/16" socket, remove the four (4) mounting bolts that secure the
heating element flange to the tank mounting flange.
5. Remove the electric heating element from the tank by pulling straight out
from unit.
6. Thoroughly clean the face of the flange to remove any particles of gasket
or sealer that remain. This will help assure a proper seal when the new
heating element and gasket are mounted.
7. Each heating element has the rated voltage and wattage listed on the
nonferrous face plate. Confirm that the rating of the replacement element
matches that of the element being replaced.
Figure 1: Detailed Drawing of EHB Type Heating Element