User Manual

I 0391 - 24
I 0391 - 25
40 mm
40 mm
GB
GB
6.6.2 - Diameter gaugeE40 mm
Place the round part of the gauge terminal on the  ange as shown
in the  gure and press
.
- The number 353 ± 1° appears on the left display .
- Turn the gauge downward position the round part of the gauge
terminal at 40 mm (radial distance) from the  ange as indicated
in the  gure.
- The number 256 ± 3° should appear on the left display.
- If not, press the button holding the gauge still at 40 mm:
the number 256 appears on the left display.
- Return the gauge to rest position.
In the event of incorrectly accessing the diameter gauge calibration
function, press to cancel it.