5.3 - Measurement result
After performing a balancing spin, the amounts of unbalance are shown on the digital readouts.
The illuminated LEDs 3 and 4 indicate the correct angular position of the wheel to mount the counterweights (12
o’clock).
Fig. 7A - Inside correction
Fig. 7B - Outside correction
5.4 - Recalculation of the unbalance
Automatic on varying set-up with the buttons
ALU
.
5.5 - Exact positioning of the adhesive weight by means of the gauge with clips
- press
If the unbalance is less than the threshold value selected,
is displayed instead of the unbalance value; with
<T
the values below the threshold can be read.
5.3.1 - Measurement precision
The machine uses special devices (WP) to ensure the best possible measurement speed and controlled measurement
precision less than 1 gr. Operation is automatic and the measurement is highlighted as soon as sufcient precision is
reached. In the event of excessive vibration of the oor or exceptional shock, the wheel balancer might execute the
maximum number of permissible measurements. In this case, the following symbol is displayed:
- Fit the correction weight in the specic gauge seat with the adhesive
part facing upwards
- bring the wheel into correct angular position for the plane to be
corrected
- withdraw the gauge until the correction plane indication arrows turn
green
INSIDE CORRECTION POSITION
OUTSIDE CORRECTION POSITION
- rotate the gauge until the correction weight adheres to the rim
- the fact that the weight application position is no longer vertical (Fig. 8)
is automatically compensated
- to cancel this function, press button again
N.B. : It is not possible to put automatically the correction
weight in the Fig.5/B position; always rotate the rim in
Fig.5/A upwards.
Correct the result all the same and check with a test launch.