User`s manual
Series VC-50 / SVC-50 / MVC-50 / LVC-50
49-MCVC50EN03 10 USER´S MANUAL
9. INTERFACE RS-232
These indicators can include an optional RS-232 interface.
Specifications:
• RS-232 interface for weighing data
• ASCII code
• 8 data bits
• Non-parity
Connector: 9 pin SUB-D type
• Pin 2: Tx
• Pin 3: Rx (not used)
• Pin 5: GND
Data format differs in normal weighing mode, item counting mode and memory total retrieval. Examples:
Normal output
When items are counted, the unit weight and count will be printed.
When the total weight stored in the accumulative memory is retrieved, the outgoing format is:
GS 12.340kg GW for gross weight, NT for net weight and unit of weight
No. 1 This number increases each time a new value is stored in the memory.
Total 12.340kg Total value stored in the memory
<lf> Includes two line-feed characters
<lf>
*************** Line of stars is shown
<lf> Includes line-feed character
TOTAL
No. 5
Weight 21.455kg .
***************
GS 12,.40kg GW for gross weight, NT for net weight and unit of weight
U.W. 123.4g/pcs The mean weight per item, calculated by the scales
PCS 100pcs Total number of items counted
<lf> Includes two line-feed characters
<lf>