Installation Guide
leaf relief
leaf relief
74
Install Leaf Relief
®
  Corners
At inside/outside corners, install 
Leaf Relief
®
 sections towards
the corner with a minimum 1/2˝ 
overlap with adjacent Leaf Relief
®
sections.
Attach Leaf Relief
®
 5˝ corners 
(IC5220/ OC5220) or 6˝ corners 
(IC6220/OC6220) using 6 screws as 
shown in the drawing. (Figure 1)
NOTE: Prefabricated corners must 
be at the same level as the Leaf 
Relief
®
 sections.
Important
Downspouts 3˝ x 4˝ or larger are 
recommended for proper function in 
a coniferous tree zone.
To prevent overflow, all inside 
corners and valleys must have a 
water diverter/deflector. Diverter/
deflector must be installed on the top 
surface of the Leaf Relief
®
 (behind 
front lip). (Figure 2)
The flow from high-level gutters 
must be transferred within 
downspouts directly into lower-level 
gutters and sealed. An alternative 
to this would be to install water 
diverters.
In applications where the Leaf 
Relief
®
 is level with the endcap.
At the end of the run, make a 4˝ cut 
on the back of the Leaf Relief
®
 up to 
the lip on the front. (Figure 3)
Cut parallel to the front about 1/2˝ 
from the lip.
Make another cut in the opposite 
direction to the lip.
Turn and fold under the excess 
material. (Figure 4)
NOTE: If Leaf Relief 
®
 is lower than 
the endcap, stop the Leaf Relief 
®
1/16” short of the endcap.
2"
2"
1/2" Overlap
Fig. 1
Fig. 2
Fig. 3