Specifications

www.whisperkool.com | Page 19
Custom Duct Work
Another Option that might be considered is building Insulated Custom Duct Work. Figure 6 below is an example 
that may be followed to create Insulated Custom Duct Work to extend to the attic using 1/2” Plywood, 1/2” Insulation 
Board and (24) Angle Brackets.
Ducting Information
When Ducting the Exhaust away from the Cooling Unit, custom Ducting will be sucient if it follows these 
recommendations:
•  Custom Ducting is insulated so that the warm exhaust air in the duct does not aect the air in the Cellar.
•  The surface area of inside the duct is greater than or equal to 51 sq. in. 
•  The Duct Work follows the General Duct Recommendations on page 21.
Measure the space between the 
cooling unit and the wall and add 
the distance to these dimensions for 
the total length.
“
“
“
“
INSTALLING THE DUCT WORK
FIGURE 6