Specifications
CellarMate Manual Page 31
Unit is Operating and Blows Evaporator Air, but the Supply Air is
Not Colder Than the Return Air from the Cellar
Possible Cause Solution
Thermostat not set up properly Check thermostat set up in the manufacturer’s
thermostat guide.
Compressor not operating High pressure switch open (button up)
Condenser air flow is blocked Remove blockage, clean filter and coil (if needed)
Head Pressure (HP) switch is
open
Reset HP switch (push button in)
Problems Controlling Cellar Temperature
Problems are occurring even though the unit seems to be fully operational—evaporator fan
blows air into the cellar and compressor and condenser fan runs.
Cellar Temperature is Too Low (Below 51°) When Unit is Running
Possible Cause Solution
Thermostat set too low on
cooling
Reset thermostat to higher cooling temperature
Heating coil (optional) not
operating
Rest thermostat to higher heating temperature
Thermostat not controlling
temperature
Wiring integrity compromised (shorted), replace
wiring
Cellar Temperature is Too Low (Below 51°) When Unit is Not Running
Possible Cause Solution
Too much heat loss to adjacent
spaces
Increase insulation around the ductwork and
doorways
Add heater