Specifications
CellarMate Manual Page 8
Installation
Pre-installation Test
Before installing your CellarMate unit, use the following procedures to test for non-visible
shipping damage.
• Set the unit of the floor or on a sturdy level surface.
• Plug the power cord into an outlet.
• Turn the main power switch to ON. The power indicator light should be on.
• Override the timer: The built-in timer prevents short cycling and keeps the
unit from turning on right away. Open the thermostat cover. Simultaneously
press the fan and UP arrow buttons. The unit will run as long as the
temperature of the space is above the thermostat set point. After several
minutes, the unit will expel cold air from the evaporator section and hot air
from the condenser section.
• Listen for unusual noise or vibration.
Air Flow Illustration
Planning the Installation
Before installation, determine the following:
• Where the unit will be located; e.g. built into the wall or mounted remotely
and ducted into the cellar.
• Where the supply and return grills will be placed to achieve preferred
temperature gradient and circulation.
• Location of the power outlet (do not use an extension cord).
• If the condenser heat exhaust will be ducted away.