Unit installation
HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
INDOOR UNIT INSTALLATION 
Install
unit
on
mounting
bracket 
Feed the line set stubs/condensate hose/ 
wiring connections through a ø 3” hole in 
the wall. 
Position the evaporator so that the “key” 
slots on the back of the unit slide onto the 
tabs on top of the mounting bracket. Then 
push the lower portion of the evaporator 
against the bracket until it latches into the 
mounting bracket. 
18,000 
Btuh 
shown
through the  wall penetration, also check 
that the  wall is plumb. The unit must be 
level and plumb for proper condensate 
removal. 
Indoor unit is now installed, it should  be 
plumb, level and flush with the wall.  In- 
sure that the line set stubs are completely 
OUTDOOR UNIT INSTALLATION 
Locate
Outdoor
unit 
Select a  location  with proper ventilation, 
minimizing recirculation possibility. Do not 
install the outdoor unit in a  location ex- 
posed to high winds (field fabricated and 
installed wind baffle may be required). 
Ensure location does not impede access 
around unit and  pose a  disturbance to 
neighboring areas. 
Install the outdoor unit on a condenser 
service pad. If unit is a heat pump ex- 
tend feet to raise 6” to allow for defrost 
to drain away. 
Clearances for the Outdoor unit: 
Front 
Condenser Fan 
9 
12” Minimum 
Service 
Rear 
Valves
Outdoor Unit 
12” Minimum 
12” Minimum 
Airflow 
Note: Consult factory if 
48” Minimum
minimum clearances can’t 
be maintained. 