Unit installation
HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
INDOOR UNIT INSTALLATION 
! 
! 
CAUTION
Follow Instructions, failure to follow 
instructions may cause possible mal- 
function and void any warranty. 
Remove
indoor
and
outdoor
units from 
the carton/box. Indoor  unit  carton  con- 
tains,  remote control and batteries, en- 
sure these are kept in a safe place during 
installation. 
Locate
 area
 to
 install
 indoor
 unit the 
unit should be located a minimum of 6 ft. 
from the floor and 6” from the ceiling. 
Choose an area where the wall is plumb 
and determine how to best to run the unit 
interconnects. 
CEILING 
6” from ceiling minimum 
from wall 
FLOOR 
Ensure no obstacles to airflow are directly 
in front of the unit, for a minimum of 12 ft 
for 9,000/12,000 Btuh units and 16 ft for 
18,000/24,000 Btuh units. 
Do not install the Indoor unit units in areas 
exposed to high humidity (Relative Hu- 
midity of 80% or more), direct sunlight and 
direct heat from stoves or other devices. 
6 
6” from ceiling m 
4ft from floor (minimum) 
6ft plus from floor (optimum) 
8”
from wall 
minimum 
8” 
minimum 