Unit installation

HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
INDOOR UNIT INSTALLATION
!
!
CAUTION
Follow Instructions, failure to follow
instructions may cause possible mal-
function and void any warranty.
Remove
indoor
and
outdoor
units from
the carton/box. Indoor unit carton con-
tains, remote control and batteries, en-
sure these are kept in a safe place during
installation.
Locate
area
to
install
indoor
unit the
unit should be located a minimum of 6 ft.
from the floor and 6 from the ceiling.
Choose an area where the wall is plumb
and determine how to best to run the unit
interconnects.
CEILING
6” from ceiling minimum
from wall
FLOOR
Ensure no obstacles to airflow are directly
in front of the unit, for a minimum of 12 ft
for 9,000/12,000 Btuh units and 16 ft for
18,000/24,000 Btuh units.
Do not install the Indoor unit units in areas
exposed to high humidity (Relative Hu-
midity of 80% or more), direct sunlight and
direct heat from stoves or other devices.
6
6” from ceiling m
4ft from floor (minimum)
6ft plus from floor (optimum)
8”
from wall
minimum
8”
minimum