Unit installation
HARBOR POINT WALL SPLIT DUCTLESS SYSTEMS
PRE INSTALLATION 
Determine the best location for mounting 
the indoor unit, it must be located a mini- 
mum of 4 ft (6 ft or more recomended) from 
the floor and no less than 6” from ceiling. 
CONTROLS AND COMPONENTS 
Units are supplied with a wireless remote 
control, which communicates with the unit 
microprocessor control.  The  return air 
temperature sensor mounted in the in- 
door unit provides input to the control for 
system operation. 
Pay attention to the air circulation in the 
room, 9,000 & 12,000 Btuh units throw air 
15ft, 18,000 & 24,000 Btuh units throw air 
25ft, ensure no obstacles to airflow exist. 
Several modes of operation are available 
to the end user depending on the type of 
comfort  required. All unit operating func- 
tions are controlled  via  the remote con- 
trol. Refer to “System Operation” section 
of this manual. 
Locate the indoor and outdoor units as close 
together as possible, maximum line set run 
and lift MUST NOT BE EXCEEDED. Deter- 
mine how the interconnect piping, wiring 
and condensate hose are to be run. 
OPTIONAL CONTROLS AND 
COMPONENTS 
Lift
Low Ambient Control: 
Please consult the factory for availability of 
approved method of  low  ambient cooling 
operation. 
Condensate Pump: 
It  is  recommended  to  use  the  supplied 
condensate  drain  hose  in  a  gravity  fed 
method  whenever  possible.  If  this  can 
not be done then a  field  installed pump 
that  is  external  to  the  evaporator  would 
be required. 
Ensure that all panels can be removed for 
service as required. 
Certification: 
All  Harbor Point Systems are  certified by  
UL    under   UL    Standard   1995.   Per- 
formance is varified  by CSA under ARI 
210/240 test standard. 
5 
Unit
Max
Line
Set
Run
Max
Vertical
HF-25/HF-35
50
Feet
17
Feet
HF-51/HF-70
50
Feet
17
Feet
HFR-25/HFR-35
50
Feet
17
Feet
HFR-51/HFR-70
50
Feet
17
Feet