Datasheet
SR1V | 261
celesco.com • info@celesco.com
tel: 800.423.5483 • +1.818.701.2750 • fax: +1.818.701.2799
15...30 vdc 1 brown
output signal 2 white
common 3 blue
n/c 4 black
output connector colorcode
signal pin (cordset)
1.7” [45 mm]
13.6 ft. [4 M]
22 AWG (.34mm
2
)
contact view
2
3
1
4
Electrical Connection
Cable Exit Direction Options
2.4” [60mm]
.25 in [6 mm]
max. cable dia.
contact view
2
3
1
4
Measuring Cable
Mounting Bracket
Electrical Connector
Rear Cover
see fig. 1
see fig. 2
see fig. 3
see fig. 4
Changing the Measuring Cable Exit and Electrical Connector Direction
Changing Measuring Cable Exit
To change the direction of the measuring cable,
remove the 4 mounting bracket screws and
rotate bracket to one of four available positions.
See gures 1 - 4 on the following pages for
mounting dimensions.
Changing Electrical Connector Direction
To change the position of the electrical connector,
remove the 4 rear cover screws and carefully sepa-
rate rear cover from the sensor body.
Rotate the rear cover to desired position being care-
ful to not tangle the wiring harness that runs to the
connector.
Factory Calibrated Stroke Range
The full scale output signal is set at the factory to the maxi-
mum full stroke range of 125 inches. The ZERO point (output
= 0 Vdc) is set at the beginning* of the stroke range (0 inches)
and the SPAN point (output = 10 Vdc) is set to the end of the
range (125 inches).
*Important — The ZERO point is set at the factory with the
measuring cable pulled out .125 inches from full retraction.
is is for the factory setting only and the ZERO may be repro-
grammed at full retraction at any time.
125 inches (3175 mm)
0 VDC
10 VDC
.125-in (3,2 mm)
Factory Set
ZERO
Factory Set
SPAN