Datasheet

SR1V | 261
celesco.com info@celesco.com
tel: 800.423.5483 +1.818.701.2750 fax: +1.818.701.2799
15...30 vdc 1 brown
output signal 2 white
common 3 blue
n/c 4 black
output connector colorcode
signal pin (cordset)
1.7” [45 mm]
13.6 ft. [4 M]
22 AWG (.34mm
2
)
contact view
2
3
1
4
Electrical Connection
Cable Exit Direction Options
2.4” [60mm]
.25 in [6 mm]
max. cable dia.
contact view
2
3
1
4
Measuring Cable
Mounting Bracket
Electrical Connector
Rear Cover
see fig. 1
see fig. 2
see fig. 3
see fig. 4
Changing the Measuring Cable Exit and Electrical Connector Direction
Changing Measuring Cable Exit
To change the direction of the measuring cable,
remove the 4 mounting bracket screws and
rotate bracket to one of four available positions.
See gures 1 - 4 on the following pages for
mounting dimensions.
Changing Electrical Connector Direction
To change the position of the electrical connector,
remove the 4 rear cover screws and carefully sepa-
rate rear cover from the sensor body.
Rotate the rear cover to desired position being care-
ful to not tangle the wiring harness that runs to the
connector.
Factory Calibrated Stroke Range
The full scale output signal is set at the factory to the maxi-
mum full stroke range of 125 inches. The ZERO point (output
= 0 Vdc) is set at the beginning* of the stroke range (0 inches)
and the SPAN point (output = 10 Vdc) is set to the end of the
range (125 inches).
*Important — The ZERO point is set at the factory with the
measuring cable pulled out .125 inches from full retraction.
is is for the factory setting only and the ZERO may be repro-
grammed at full retraction at any time.