Owner`s manual

Controls Setup & Commissioning
P
ROFILE
S
ERIES
O
WNER
S
M
ANUAL
TEK600
S
ERIES
C
ONTROL
Page 18
Setting the Thermostat Control Minimum / Maximum speed settings.
1. Start with the wall switch in the off mode.
2. Press and hold the auto and timer buttons for ten seconds then release, after releasing
these two buttons press and release the timer button once.
3. The auto light will flash continuously and the four-hour light will flash once every two
seconds, this indicates that the unit is ready for low speed adjustment. If this does not
occur repeat steps 1 and 2.
4. Rotate the adjustable dial fully anti-clockwise and press the fan button once, the fan light
will flash three times to confirm the new setting has been entered.
5. To increase the minimum speed setting rotate the dial clockwise to a desired set point
and press the fan button to enter the new setting. (NOTE: The fan speed will not change
until the fan button has been pressed).
6. If the minimum speed needs to be increased further rotate the adjustable dial and press
the fan button to enter the new setting.
Once the minimum speed has been set press the auto button to adjust the high speed
setting (go to step 7) or press the timer button once to escape the minimum and
maximum speed setting mode and return to normal wall switch operation.
7. Once the minimum speed has been set press the auto button once and the auto light will
flash continuously and the four hour light will flash twice every two seconds, indicating
that the unit is ready for maximum speed adjustment.
8. Rotate the adjustable dial fully clock-wise and press the fan button once to enter the new
setting.
9. If the maximum speed needs to be decreased rotate the dial anti-clockwise then press
the fan button to enter the new setting.
10. If the fan speed needs to be decreased further repeat step 9.
11. Once minimum and maximum speeds have been adjusted press the timer button once to
escape the minimum and maximum speed setting mode and return to normal wall switch
operation.
H
AND
O
VER
The evaporative air conditioning unit will now be ready for operation and hand over to the
customer.
1. Setup up the control to the customer’s requirements e.g. MANUAL or AUTO.
2. Explaining the key features of the control that they will use.
3. Explain the operation of an evaporative air conditioner and the key responsibilities of the
customer e.g.:
Continuous Bleed requirement
Dumping cycles (If dump valve is fitted)
Venting the air via the side of the home the wind is not blowing from.
Maintenance requirements
4. Present the customer with their Owner’s Manual for further explanation of the product’s
operation.