Parameter Settings Table
The below table is a parameter chart for setting the unit.
This chart is also printed on the back of the wall switch.
Setting Installer Parameters.
Press and hold the FAN+TIMER buttons for 10 seconds, release, and press the TIMER
button once
Parameters Dump delay Pre-cool Dump interval Pre-fill
Parameter indicator 2hr light 4hr light 8hr light 2+4hr light
OFF
• •
•
ON
• • (default)* • • (default)*
• • (default)*
0HR
• (default)*
1HR
• •
2HR
• • •
4HR
• • • •
8HR
• • • • •
12HR
• • • • • •
Parameter
setting
(Number of
AUTO light
flashes)
24HR
• • • • • • •
* Note: the default settings in the above table are factory set.
Entering the Parameter Setting Mode
To enter and adjust the parameter setting mode follow the instructions below:
1. Start with the wall switch in the off mode.
2. Press and hold the both the FAN and TIMER buttons together for 10 seconds.
Release both buttons and press the TIMER button once.
3. The 2hr light will turn on and the AUTO light will flash. At this point the control is ready
for any settings to be entered into the wall control.
Setting the dump delay
(2 hour light on and Auto light flashing)
1. To set the dump delay to dump 40 seconds after the pump turns off, rotate the dial fully
to the minimum position and the auto light will flash once every two seconds.
2. To set the dump delay to dump 1 hour after the pump has switched off, rotate the dial
fully to the maximum position and the auto light will flash twice every two seconds.
3. Press the FAN button once to select the desired mode. (The fanlight will flash three
times to confirm the setting).
4. Press the AUTO button to go to the next setting (go to step 6) or press the TIMER button
to cancel.