CONTROL SETUP & COMMIS SIONING
Your evaporative air conditioner has been supplied with the Climate Low voltage control
featuring basic control options and thermostat, timed delayed starting and stopping, and
dump valve features.
This low voltage controls are connected to the air conditioner control box via a 20-metre low
voltage loom.
NOTE: Do not run the low voltage loom in long parallel runs with 240V mains
cables.
Keep the low voltage loom 200mm away from any long runs of mains
wiring.
Cross over mains wiring at right angles.
Do not use existing access holes in wall cavities where 240V mains
wiring exist. Drill a new access hole 200mm from the existing hole.
S
AFETY
Switch OFF the power and unplug the unit before touching any wiring or performing
any work.
A QUALIFIED ELECTRICIAN must carry out all 240-volt electrical work.
B
EFORE
C
OMMENCING
Packaging
Upon delivery, check that there is no damage to the unit. Any damage should be reported
to your nearest Climate Technologies sales outlet.
Is the control system correct?
Check the customer order to ensure that you have all the correct equipment for installation.