User guide

ZIC2410 Getting Started Guide
Rev E Document No. 0005-05-08-11-001 Page 20 of 22
3) While in this window, type the new serial number (e.g.0004), in the lower
‘Serial Number’
box
and check the
‘radio box’
to its left.
4) Press the
‘Program Device’
button. The upper
‘Serial Number
box will become blank as
shown in Figure 16.
Figure 16 – Screen, CP210x Set IDs (Executing ID # Change)
If the serial number selected has not been used before on this PC, the user will be prompted that two
new hardware devices have been found. Follow the procedure given in Section
Error! Reference
source not found.
of this document to install the two new devices.
5) Once both hardware devices have been installed click on
‘Update Device List’
and the serial
number will be changed to
‘0004’
as shown in Figure 17.
Figure 17 – Screen, CP210x Set IDs (ID # Change Complete)
6) To ensure that the process has been completed successfully, the user can check in
Device
Manager
. In
‘Ports (COM & LPT)’
double-click on the new
‘CP2101 USB to UART…’
port
(Note that it has a new COM port number (See Section 4.1.2 for instructions on using Windows
‘Device Manager’
).
7) Under the
‘Details’
Tab, the new ID number will be displayed as shown in Figure 18.
Figure 18 – Screen, Device Manager (Checking ID # Change)