User manual
1. GENERAL INFORMATION
Thank you for your purchase of CEL-MAR Company product. This product has been completely tested and is covered by a two year
warranty on parts and operation from date of sale.
If any questions or problems arise during installation or use of this product, please do not hesitate to contact Technical Support at +48
41 362-12-46 or e-mail support@cel-mar.pl.
1.1. WARRANTED INFORMATION
CEL-MAR Company gives the indefinite guarantee on the ADA-13021 converter. The warranty does not cover damage caused from
improper use, materials consumption or any unauthorized changes. If the product does not function accordance with the instructions
will be repaired. All warranty and no warranty repairs must be returned with paid transport and insuring to the CEL-MAR Company.
CEL-MAR Company under no circumstances won't be responsible for ensuing damage from improper using the product or as a result
of random causes: the lightning discharge, the flood, the fire and the like.
CEL-MAR Company is not be held responsible for damages and loss including: loss of profits, loss of data, pecuniary losses ensuing
from using or the impossibility of using this product.
In specific cases CEL-MAR Company discontinue all warranties and in particular do not follow the user manual and do not accept
terms of warranty by the user.
1.2. GENERAL CONDITIONS FOR SAFE USE
The device should be installed in a safe and stable places (eg, electroinstallation cabinet), the powering cable should be arranged so
as not to be exposed to trampling, attaching, or pulling out of the circuit.
Do not put device on the wet surface.
Do not connect devices for nondescript powering sources,
Do not damage or crush powering wires.
Do not make connection with wet hands.
Do not adapt, open or make holes in casings of the device!
Do not immerse device in water or no other liquid.
Do not put the fire opened on device sources: candles, an oil lamps and the like.
Complete disable from the supply network is only after disconnecting the power supply circuit voltage.
Do not carry out the assembly or dis-assembly of the device if it is enabled. This may result to short circuit and damage the device.
1.3. CE LABEL
CE symbol on organizing the company CEL-MAR a conformity of the device to the directive of the electromagnetic EMC
2004/108/WE compatibility means (Electromagnetic Compatibility Directive). The declaration of the agreement is
accessible through the contact with the technical service at the address e-mail: serwis@cel-mar.pl or on the phone at the
+48 41 362-12-46.
1.4. ENVIRONMENTAL PRESERVATION
This sign on the device inform about putting expended device with other waste materials. Device should send to the
recycling. (In accordance with the act about the Electronic Appliance Expended from day 29 of July 2005)
1.5. SERVICE AND MAINTENANCE
The ADA-13021 converter does not require the servicing and maintenance.
Technical support is available at number +48 41 362-12-46 in 8.00-16.00, from Monday to Friday or e-mail support@cel-mar.pl.
2. PRODUCT INFORMATION
The converter is delivered with: User Manual and ADANet software CD.
2.1. PROPERTIES
● Operating on ETHERNET network- IEEE 802.3 standard,
● 10/100BaseT physical layer,
● Connecting via Rj45 connector,
● Baud rate 10/100Mbps (auto-sensing),
● Full or half duplex (auto-sensing) operate modes,
● Protocols: TCP, UDP, DHCP, SNMP, SSL/TLS, Telnet, Rlogin, LPD, HTTP/HTTPS, SMTP, ICMP, IGMP, ARP,
● Integrated WWW sever for converter configuration,
● Configuration of net services according to user personal setting,
● Static or dynamic IP address (added by DHCP server),
● Diagnostics of serial and network port,
● Encoded transmission: DES (56-bit), 3DES (168-bit), AES (128/256-bit),
● Operating modes: virtual serial port, serial bridge TCP, serial bridge UDP, TCP sockets, UDP sockets,
● Operating on 4-wire line in Current Loop standard,
● Current Loop baud rates (bps): 50, 75, 110, 134, 150, 200, 300, 600, 1200, 1800, 2400, 4800, 9600, 14400, 19200, 28800, 38400,
● Current Loop data format - Number of data bits: 5, 6, 7, 8; Parity checking: None, Odd, Even, Constantly 1, Constantly 0; Stop Bits:
1, 2,
● Transparent for all protocols, which the data format is compatible with the above specifications of Current Loop interface eg
MODBUS,
● Power supply 10 - 30 VDC stable min. 3W,
● ~ 3000V= optoizolation in signal channel between ETHERNET and Current Loop interfaces,
4