User manual

7. FACTORY DEFAULT
Parameter Value
User name root
Password dbps
Operating mode RealPort
Bout rate[bits/sec] 9600
Number of data bits 8
Parity Control no
Number of stop bits 1
Flow Control no
8. PROBLEMS
Problem Solution
I forgot the password
Restoring Default Settings according to steps below:
1. Disconnect the power of the converter,
2. Remove the cover of ETHERNET connector,
3. Press RESET “RST” and holding the button, connect the power
of the converter,
4. Release the button after 20 sec. when the converter will start
with default settings.
Restoring Default Settings deletes existing configuration and the
proper configuration should be loaded to the converter form the
backup.
I changed the configuration and the converter isn't functioning.
1. Enter in the Internet browser http://converter-ip-address,
2. Select the menu [Factory Default Settings] press [Restore].
9. VERSIONS
ADA-13021 - - -
Order example:
Product Symbol: ADA-13021-1-2-2
1 – basic version of electronic,
2 – 12VDC / 0-20mA (TTY) Current Loop type,
2 – 1kV= galvanic isolation.
Electronic versions:
Basic
1
Current Loop type:
24VDC / 20mA – active/passive transmitter/receiver
1
12VDC / 20mA (TTY) - active/passive
transmitter/receiver. Standard version
2
Galvanic isolation:
1kV DC
2
3kV DC
3
24
ADA-13021