User manual

Fig. 22. Example configuration of the UDP server&client on converter connected to SLAVE device
ATTENTION !
Default port of serial port service is 2101.
If on the local network is conflict with other network service using the same port, in the converter's port configuration
change number of port into another for the server and client service .
5.2.2.1.3.3. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATION
For proper operation of ADA-13021 with device connected to his serial port (Current Loop), should be set the same transmission
parameters for both devices.
Select Basic Serial Settings and enter Baud Rate, Data Bits, Parity, Stop Bits, the same parameter like has device connected to
the serial port of the converter.
5.2.2.1.4. SERIAL BRIDGE PROFILE CONFIGURATION
Choosing the Serial Bridge (Fig.18) profile enable direct communication between two devices connected to two ADA-13021
converters over the network as if they were connected with a serial cable. A properly configured ADA-13021 will start automatically
communication with each other. Press [Apply] for save the configuration
After saving the Serial Bridge profile, will open section Serial Bridge Settings (fig. below) with operating parameters like on picture
below. Select Initiate serial bridge to the following device option and enter IP address and 2101 port of the converter with which to
create the serial bridge over the network. Additionally can be selected [Enable TCP Keep-Alive] option which keeps connection even
if the data is not transmitted. Select Allow other devices to initiate serial bridge and enter 2101 port on which other the converter
will automatically start communication and can be set also [Enable TCP Keep-Alive] option which keeps connection even if the data
is not transmitted.
19
ADA-13021