User manual

Fig. 21. Example configuration of the UDP server&client on converter connected to MASTER device
5.2.2.1.3.2. UDP CLIENT & SERVER CONFIGURATION IN CASE OF SLAVE DEVICE
Set operating parameters of UDP server on the converter connected to SLAVE device eg. like on picture below. Set an access to UDP
server on e.g. 2101 port. Then select Automatically send serial data in section UDP Client Settings, this automatically send
received data by the use UDP client service to the MASTER device connected to LAN / WAN through e.g. ADA-13020, ADA-
13028L, ADA-13040MG, ADA-13110, ADA14040, ADA-14040.
On lists Send data to the following network services are addresses of network devices and ports to which will be send data. In
field:
Description - enter e.g. location of the converter and MASTER device,
Send To - enter IP address of converter connected to MASTER device,
UDP Port - enter the number of port on which is working UDP Server of converter connected to MASTER device
In the section Send data under any of the following conditions is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for SLAVE device, press [Apply].
18
ADA-13021