For configuration of TCP Client Settings (TCP Client Setting, fig. below), select Automatically establish TCP connections,
connection between client and TCP server will be automatically. Then select Always connect and maintain connection option and
in section Establish connection to the following network service enter IP address of device to which TCP client will send data,
select service and enter port. There is also possible to select an option Enable TCP Keep-Alive – connection will be kept, even if the
data is not transmitted over the network.
For saving the configuration press [Apply].
Fig. 20. Example configuration of TCP client
ATTENTION !
Default port of serial port service is 2101.
If on the local network is conflict with other network service using the same port, in the converter's port configuration
change number of port into another for the server and client service .
5.2.2.1.2.2. SERIAL PORT TRANSMISSION PARAMETERS CONFIGURATION
For proper operation of ADA-13021 with device connected to his serial port (Current Loop), should be set the same transmission
parameters for both devices.
Select Basic Serial Settings and enter Baud Rate, Data Bits, Parity, Stop Bits, the same parameter like has device connected to
the serial port of the converter.
5.2.2.1.3. UDP SOCKETS CONFIGURATION
Choosing UDP Sockets (Fig.18) is configured the serial port of ADA-13021 converter for direct communication with PC or other
device connected to the network by the use of UDP socked. Data sending by application or other device/s to this port are transferred
through LAN/WAN to ADA-13021 converter and are present on his serial port. Press [Apply] for save the configuration.
5.2.2.1.3.1. UDP CLIENT & SERVER CONFIGURATION IN CASE OF MASTER DEVICE
After saving the UDP Sockets profile, will open section UDP Server Settings with operating parameters like on picture below. Set an
access to UDP server on e.g. 2101 port. Then select Automatically send serial data in section UDP Client Settings, this
automatically send received data by the use UDP client service to the SLAVE device connected to LAN/WAN through e.g. ADA-13021
ADA-13020, ADA-13028L, ADA-13040MG, ADA-13110, ADA-14040, ADA-14040.
On lists Send data to the following network services are addresses of network devices and ports to which will be send data. In
field:
– Description - enter e.g. location of the converter and SLAVE device,
– Send To - enter IP address of e.g. converter, connected to SLAVE device,
– UDP Port - enter the number of port on which is working UDP Server of converter connected to SLAVE device
In the section Send data under any of the following conditions is recommended to set parameters like on picture bellow.
For saving the configuration of UDP client and server for MASTER device, press [Apply].