Dear Customer We congratulate you for intelligently choosing CEIL Static UPS that incorporates latest DSP controlled IGBT base technology. This manual provides you a thorough understanding of your Static UPS and its optimum use. Please read the installation and operating instructions in this manual carefully before installing and using your CEIL Static UPS. Pay special attention to the section under PRECAUTIONS.
Contents Topic Page no.
Knowing your Static UPS A static UPS ensures uninterrupted power supply to large electrical loads of commercial and residential establishments during power outage. In its most basic form, a Static UPS transforms Alternating Current (AC) to Direct Current (DC) for providing the required charging current for the Battery Bank connected with it and also, to convert Direct Current (DC) of the Battery Bank to Alternating Current (AC) for the electrical loads.
REAR Panel Position No. 3 4 5 6 7 8 9 10 11 12 Function Fan Inbuilt time Delay AC Mains MCB Battery MCB AC Mains Output Battery Terminal Negative (Black) Battery Terminal Positive (Red) BYPASS switch Inverter/UPS Remarks For cooling the Unit To run compressor load like A.C.Time delay relay (TDR) has been provided.
Display Status Status On Display Alarm IUPS I/P……………………..Volt No running on mains O/P…………………… Volt I/P Freq……………..Hz O/P Freq…………… Hz Battery Charging Battery ………………Volt Mains OK Load……………………% Battery Low Protection Battery Low Beeping Output over load Warning Beeping Overload I/P MCB Trip I/P MCB Trip Beeping O/P Short Circuit Protection Short Circuit Beeping UPS on Battery Mains not OK Beeping Every 5 Min. I/P……………………..Volt O/P…………………… Volt I/P Freq……………..
SOME SAFETY MEASURES Important Precautions: CEIL DSP Sine wave Static USP has two Battery terminals coming out from the rear side, an AC MCB, a DC MCB, an AC output socket and an AC Input socket. Battery terminals are red and black in colour. The red colour terminal has to be connected to the POSITIVE TERMINAL of the battery and black one to the NEGATIVE TERMINAL. CAUTION: Do not reverse the battery connections as it will trip the Battery MCB/ Fuse.
CAUTION: The CEIL DSP Sine wave Static UPS should be connected to grounded, permanent wiring systems. Personal Precautions: A person should be within the range of your voice so as to come to your aid when you work near batteries Keep plenty of fresh water and soap nearby in the event that battery acid comes in contact with skin, clothing or eyes. Avoid touching eyes while working near batteries; Wash your hands when work done.
CONCEPT OF CHARGING Five Stage Pulse Charging Bulk: Batteries are charged at maximum allowed continuous constant charging current at constant voltage for speedy charging of battery up to 13.8V (for a 12V battery). Boost: The charger checks the charging current when the battery voltage reaches 13.6V for 12V batteries. The boost mode of the charger will be activated, which will boost the battery up to 20% more than its rated voltage (14.
GETTING STARTED Environment Static UPS / Inverters are sophisticated devices and must be treated accordingly. Keep the Static UPS in a non-condensing, well-ventilated environment, ensuring there is no ingress of moisture or foreign material. Location Static UPS should be kept as close as possible to the battery in order to keep the battery cables short.
INSTALLING YOUR STATIC UPS Mounting Mounting the Static UPS in a ventilated enclosure with sealed batteries is acceptable. Avoid mounting the Static UPS in a closed container. To operate at high power for sustained periods of time unrestricted airflow is required. Without the protection, circuitry will activate and reduce the maximum power available or cause complete shutdown of the Static UPS. As per standards, Static UPS should be mounted on a flat surface.
AIR CONDITIONER WIRING The air-conditioner requires a 5 minute delay each time the supply is interrupted. To provide for the time delay, a socket (TDR) is provided at the back panel of Static UPS. WARM UP Secure all the wiring with ties or other non-conductive fasteners to prevent damage. Switch on DC MCB. Check the front LCD panel. Switch on the front panel switch and verify the Static UPS operation. Switch on AC MCB and give AC mains to the Static UPS.
Installation Diagram For Static UPS
Technical Specifications
Trouble Shooting
Static UPS Test Report Tested by …………………………………………………… Inspected by……………………………………………… Date…………………………………………………………… Date………………………………………………………….. Sign……………………………………………………………. Sign…………………………………………………………….
Installation Check List Environment Place Remarks Noise Dust Without Cooling With Cooling Ventilation Distance Between UPS and Walls Y/N Y/N Y/N Y/N Y/N METER Mains Side Rating of I/P Circuit Breaker I/P Wire Thickness Back Up System Capacity (DG Set Capacity and Make) Mains Stabilizer capacity and make (if any) No. of Earthing Pit Mains Voltage Mains N-E Voltage Mains Frequency Back Up System (DG Set)Frequency AMP sq. mm. KVA 1Ph./3Ph KVA 1Ph.
Customer Awareness Static UPS /Inverter Technology use : DSP Sinewave Capacity of Inverter : ……………..VA No. of Battery use/DC voltage : ………..Nos / ……………Volt DC Input Voltage range : (120V-280V) in normal mode (180V-260V) in UPS mode Output voltage : 230 Volt AC Output current at full load : ……………….AMP Output frequency : 50HZ+/- 1.