8
PROGRAMMING CONTINUED…
• Be sure to log your entries here for future reference:
# 0 0 1 _ _ 0 0 _ 0 _ 0 _
1 2 3 4 5 6 7 8 9 10
EXAMPLE: Dial #00 1060000005. The telephone will be set as follows:
Digit 1- Always 1.
Digit 2- N0 incoming calls allowed.
Digit 3- 6 minute conversation time out.
Digit 4- Always 0.
Digit 5- Always 0.
Digit 6- ADA feature activated.
Digit 7- Always 0.
Digit 8- Do not dial PBX access number.
Digit 9- Always 0.
Digit 10- 250 Ms wink detect.
3.09 Press the “CALL" button to hang up the phone and return the mini-jumpers
to the "OFF" position, as depicted on the last page of this manual.
4.0 TESTING/OPERATION
4.01 With the telephone connected to a working telephone line, press the
“CALL” button located on the front of the telephone. The LED will illuminate
red at this time. The blue strobe light will not function until AC power has been
supplied to the phone (see section 7.0). When AC power is available, the strobe
light will activate when the CALL button is pressed and it will stay activated
until the call is terminated. The call is terminated when the CALL button is
pressed again, when the automatic call disconnect time limit expires, or when
the far end hangs up returning a wink back on the line.
4.02 If any PBX or access number was programmed, it will automatically dial out
before the programmed auto-dial number. There will be an approximate one (1)
second pause between the two numbers. If this does not work, please repeat
sections 3.02, 3.03, 3.04, 3.06, 3.08, and 3.10 only
. If trouble is still
experienced, please refer to section 11.02.