Service manual

Issue 4.0
CEECO
Communication Equipment & Engineering Company
PROPRIETARY
7
PROGRAMMING CONTINUED…
3.08 Enter # 0 0 followed by a series of ten (10) digits selected from the options
below. Some of the digits allow a choice and others simply provide an arbitrary
number. An entry must be made for each of the ten digits, in order for the phone
to be properly programmed.
#00:
Digit 1
1 Always 1 for this model.
Digit 2
0 No incoming calls allowed.
1 Incoming calls allowed.
Digit 3
0 No conversation time-out.
1-9 Minute(s) conversation time-out.
Digit 4
0 Always 0 for this model.
Digit 5
0 Always 0 for this model.
Digit 6
0 Deactivate ADA feature.
9 Activate ADA feature.
Digit 7
0 Always 0 for this model.
Digit 8
0 Do not dial PBX access number stored in location #18.
1 Dial PBX number stored in location #18.
Digit 9
0 Always 0 for this model
Digit 10
0 No wink detect.
1-9 Length of the wink detect.
(1=50ms incremental to 450 ms. 5 is recommended).