Canadian DN-60705:A1 • 9/19/2011 — Page 3 of 4
Product Line Information
NSP-25C: 25 point addressable fire alarm control panel.
Includes main circuit board, chassis, backbox and door. Black;
120 VAC. Listed for Canadian applications.
Note: For versions used outside Canada, see DN-60703.
HONEYWELL FIRE SYSTEMS DEVICES
HFS-PA: Honeywell Fire Systems addressable photoelectric
smoke detector. Includes base.
HFS-PTA: Honeywell Fire Systems addressable photoelectric
smoke detector with thermal sensor. Includes base.
HFS-TA: Honeywell Fire Systems addressable fixed tempera-
ture heat detector. Includes base.
HFS-MMA: Honeywell Fire Systems addressable Mini-Monitor
module for normally-open contact devices.
HFS-MRA: Honeywell Fire Systems addressable relay mod-
ule.
HFS-DA: Honeywell Fire Systems addressable photoelectric
duct smoke detector. Includes detector.
NOTIFIER EQUIVALENT DEVICES
NOT-BG12LX: Addressable dual-action manual pull station.
NP-100A: Addressable low-profile photoelectric smoke detec-
tor.
NP-100TA: Addressable low-profile photoelectric smoke
detector with thermal sensor.
NH-100A: Fast-response, low-profile heat detector.
DNRA: InnovairFlex low-flow non-relay duct-detector hous-
ing; uses NP-100RA (ordered separately).
NP-100RA: Addressable remote test capable detector for use
with DNRA duct smoke detector housing.
NMM-100PA: Miniature version of FMM-1A. Excludes LED
and Style D option. Connects with wire pigtails. May mount in
device backbox.
NC-100RA: Addressable relay module containing two isolated
sets of Form-C contacts, which operate as a DPDT switch.
N100-ISOA: This module isolates the SLC loop from short cir-
cuit conditions
COMPATIBLE ANNUNCIATORS
N-ANN-80C: Remote fire alarm indicator mimics the informa-
tion displayed on the FACP LCD display. Recommended wire
type is un-shielded.
N-ANN-SB80KIT-R: Red surface mount backbox with angled
wedge.
N-ANN-SB80KIT-W: White surface mount backbox with
angled wedge.
MISCELLANEOUS
SB-I/O: Surface-mount backbox for the NOT-BG12LX, plastic.
BG12TR: Optional trim ring for semi-flush mounting the pull-
station.
BB-26: Battery backbox, holds up to two 25 AH batteries and
CHG-75.
NFS-LBB: Battery box, houses two 55 AH batteries.
CHG-75: Battery charger for lead-acid batteries with a rating
of 25 to 75 AH.
CHG-120: Remote battery charging system for lead-acid bat-
teries with a rating of 55 to 120 AH. Requires additional NFS-
LBB for mounting.
BAT Series: Batteries.
See DN-6933.
007860: DACT Phone Cord (2 required)
Wiring Requirements
While shielded wire is not required, it is recommended that all
DCL wiring be twisted-pair to minimize the effects of electrical
interference. Refer to the panel manual for wiring details.