ASSEMBLY AND OPERATION INSTRUCTIONS
Figure 5
ELECTRICAL WIRING
Any electrical re-wiring of this appliance must
be done by a qualied electrician. This wiring
must be done in accordance with local codes
and/or in Canada with the current CSA C22.1
Canadian Electrical Code, and for US instal-
lations, the National Electrical Code ANSI/
NFPA NO 70.
WARNING: If repairing or
replacing any electrical compo-
nent or wiring, the original wire
routing, color coding and secur-
ing locations must be followed.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger-
ous operation.
WARNING: Never attempt
to service fan/blower while it is
plugged in, operating, or hot.
Burns and electrical shock could
result. Only a qualied service
person should service or repair
fan/blower.
Verify proper operation after servicing. If any
of the original wire as supplied with the appli-
ance must be replaced, it must be replaced
with a wire of at least a 105º C temperature
rating.
Grounding Pin
Grounding Means
Metal Screw
Cover of
Grounded
Outlet Box
A
B
C
Adapter
Figure 4
Motor
Black
Green
White
Switch
Thermostat Switch
AUTO
O
MAN
FAN OPERATION
To operate the manual unit, turn ON/OFF
switch to the ON position. To operate the
Automatic unit, turn AUTO/O/MAN switch to
the desired position. MAN position will remain
constantly on. AUTO position will be controlled
by the sensor on the fan blower unit. The sen-
sor will be activated when the temperature of
the sensor head reaches the set point of the
switch after the heater is started. To stop the
operation, turn the switch to the O position.
GROUNDING INSTRUCTIONS
This fan/blower is for use on 120 volts. The
cord has a plug as shown at A in Figure 4.
An adapter as shown at C is available for
connecting three-blade grounding-type plugs
to two-slot receptacles. The green grounding
lug extending from the adapter must be
connected to a permanent ground such as
a properly grounded outlet box. The adapter
should not be used if a three-slot grounded
receptacle is available.