Specifications
TROUBLE SHOOTING GUIDE
WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal
components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper
contact
PROBLEM PROBABLE CAUSE REMEDY
1
Brewer Does Not
Brew
No power at outlet
Circuit Breaker tripped due to overloaded outlet.
2
No Spray from
Spray head
Brew Switch Off
No Water in Trough
Air Locked
Flow Switch
Clogged Up
Flow Switch
Activate Brew Switch
Pour 1 Decanter through Opening
Warning: 2 Decanters Maximum
Bump Side of Brewer to Release
Airlock.
Unplug Unit; Remove Front Cover, Remove
Flow Switch and Clear Switch by Blowing Out
Obstructive Material (scale).
3
Brewer Performs
Poorly, Steams
Excessively
Restricted Flow Switch
Clogged Spray Head
Overflow Tube Slipped Out
of Accumulator Assembly
Allowing Hot Water To Heat
Up Water In Trough
Remove and Clean Flow Switch
Remove and Clean Spray head
Remove Top Cover. Connect
Over flow Tube to Accumulator
4
Brewer Takes too
Long To Brew
Limed Up Generator
De-lime Generator (See De-liming Procedure)
5
Brewer Still Does
not Brew When
Power Is On and
Brew Switch, Flow
Switch and Power
Relay Checks Out
O.K.
Heating Element Inside
Generator Assembly
Defective
Bad or Incorrect Wiring
Remove and Replace Generator
Assembly.
Check Wiring of Components Against Wiring
Diagram.
Check for Loose Connection.