Specifications
ADJUSTMENTS
TO BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY.
Caution:
Brewer should be unplugged from electrical outlet before any service is performed.
The water flow rate coming from the hot water tank is constant/fixed at 0.75 gal/min.
Increasing or decreasing the amount of hot water dispensed from tank can also be used
to adjust the strength of the tea.
The Longer water flows - More water - Weaker tea; Less water flows - Less water - Stronger tea.
The TB-3 & TB-5 Brewer will complete a full cycle in approximately 5 TO 10 min.
1. BREW TIMER ADJUSTMENT (mounted inside top housing).
Controls the brewing time (min.) for brewing Coffee and Hot Tea Concentrate
Factory set at 3 min. for brewing 3 liters [3/4 gal.] of Tea Concentrate.
[later to be diluted with 2 1/4 gal. of cold water which makes up the
total 3 gal. Iced tea].
To increase or decrease dispensing time and volume of hot water dispensed, turn knob
in the direction shown on timer.
Note: The brewing time, temperature, and amount of product used in the funnel
effects the drink strength. See chart of Tea Flavors and Grams to be used.
TO RESET TO FACTORY SETTINGS:
*Push the Brew Button (HOT TEA), then adjust Timer to 3 or 5 min. [for 3 or 5 gal.] depending on the
water pressure in the main water line.
*Adjust the Dispense Valve 1/4 turn at a time, if necessary, to increase or decrease the Hot Water Flow.
*Push the Brew Button (ICED TEA), then adjust the Timer to 3 min. or 5 min. [for 3 or 5 gal.] depending
on the water pressure in the main water line.
3. COLD WATER DILUTION
DELAY TIMER ADJUSTMENT (located inside the unit, near the water inlet valve).
Set Delay Timer knob approximately as shown in picture. This setting corresponds to a delay time
of 1.5 minutes after the hot tea begins to dispense. If the water pressure requires a different setting
on the Cold Water Timer, then the Delay Timer also needs to be adjusted so that it delays the Cold
Water 1.5 minutes after the hot tea begins to dispense.
SPECIAL ORDER
This setting corresponds to a delay time of 5 minutes after the hot tea finishes despensing.
If the water pressure is higher than 20 PSI, decrease the setting on the Cold Water Timer and Delay Timer.
If the water pressure is lower than 20 PSI, increase only the setting on the Cold Water Timer to Max.
L265A
BREW TIMER
L595A