Specifications

Hot Water Dispenser - HWD5
Tomlinson faucet Manual dispense
29.0
29.8
15.3
12.09.3
0.7
7.0
Electrical Specifications
MODEL NO WATTSVOLTS
PHASE
& CYCLES
RECEPTACLE
Operational
MODEL NO
INITIAL
HEAT-UP TIME
BURST
CAPACITY
RECOVERY GALLONS
PER HOUR
TANK
CAPACITY
HWD5
1700120 1 PH. 50/60 Hz
P5-15
R5-15
30-45 Min
2.0 Gals
20-25 Min 5.0
5.0 Gal
HWD5
Heat-up time and Dispense rate based on Inlet water temperature at 68°F and
Dispense water temperature range 165°F to 200°F
3000240 1 PH. 50/60 Hz
P6-15
R6-15
20-25 Min 15-20 Min 9.0
3.0 Gals
VOLTS
120 (1.7 KW)
240 (3.0 KW)
1.3
6000240 1 PH. 50/60 Hz
P6-30
R6-30
15-20 Min
10-15 Min 14.04.0 Gals
240 (6.0 KW)
Water Connection
Water pressure: 20 - 90 PSI (69 - 621 KPA) Supplied with ¼ OD male flare fitting
Export units add "X" to Model No.
Specify Voltage and type of line cord required.
POWER CORD
(included)
IMPORTANT
- BEFORE REMOVING TOP PANEL -
DISCONNECT POWER
REMOVE BOTTOM PANEL
AND DRAIN TANK
Page -5-