Operator`s manual
GIANT UL BLACK
7
ENGLISH
properly engaged (see figure 18).
figure 18
8 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1 - Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM available chlorine
concentration or 1 spoon of sodium hypoclorite diluted with
2 liters of water) according to your local Health Codes and
manufacturer’s specifications.
2 - Pour the solution into the bowl(s).
3 - Using a brush suitable for the purpose, wipe the solution
on all surfaces protruding above the solution-level and on
the underside of the top cover(s).
4 - Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution
out of the bowl(s).
5 - Use fresh product to chase any remaining sanitizer from
the bottom of the bowl(s). Drain this solution. Do not rinse
out the machine.
6 ROUTINE MAINTENANCE
1 - Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication,
worn or damaged parts. Replace parts as needed.
2 - Monthly: remove the dust from the condenser filter. A
blocked filter will reduce performance and could cause
compressor failure.
Remove the only left panel (from faucet side) unscrewing
the two plastic coated screws (see figure 19).
figure 19
3 - Replacement of lighted top cover bulbs: remove the fixing
screw located in the upper part of the cover, lift the socket
and replace the bulbs. Reassembly the support and the
fixing screw. (see figure 20)
figure 20
6. 1 MAINTENANCE (TO BE CARRIED OUT
BY QUALIFIED SERVICE PERSONNEL
ONLY)
1 - Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
2 - When installed, the anti-splash filters inside the slotted
panels must not be removed.
3 - Never remove the insulating jacket from around the
suction tubing of the evaporator (the copper tubing located
on the right side of gear motor). In case the insulating
jacket is missing replace the entire parts with original
spare parts from the supplier.
4 - In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied
by the manufacturer or with another lubricating product
suitable for polycarbonate.
ATTENTION
Before any disassembly and/or cleaning procedure
make sure that the dispenser is disconnected from its
power source by unplugging it or switching off the 2-
pole wall breaker.
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
IMPORTANT
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.