Specifications
ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-82
up vertically 3"H. w/ 1 ½" flat top, turn down 1-1/2".
C. Punch the top for and mount the food waste collector per
manufacturers recommendations.
D. Mount top on standard Open Frame Base. (2) ―H‖ leg sets, one
either side of the food waste collector. Each leg set with
flanged foot on front leg, set in sealant and securely anchored
to the floor. Note; Item D2 - Food Waste Collector a minimum
of 24" from dish machine.
ITEM NO. D7 - HOSE REEL; UNDER COUNTER
REQUIRED
A. Provide as detailed, exposed reel rinse with spray valve,
mounting base & hose support arm rotated with hose off top of
reel and spray head supported off the floor, 35' of hose.
Provide 12 ga. S/S fixture support bracket, 8"W. x 6"H. Provide
with 60
o
top to bottom tapered sides turned back 90
o
from the
face. Top of side to have 1" 90
o
inward return which welds to
table bottom. Face of bracket punched for control valve. Radius
bottom corners ½". Weld stud bolts to top under side, secure
hat channels for reel rinse mounting, mount reel rinse and
control valve bracket.
1. Stainless Steel Exposed Hose Reel; Exposed reel rinse
w/spray valve; all stainless steel; 35 feet of 3/8" ID, 3 ply,
2 braid hose, working pressure of 150 PSI & withstands 140
F water temp., ½" NPT female; adjustable arm positions allow
ceiling, wall, under counter mounting.
c. Fisher 29610. In lieu of standard, provide with Ultra
Spray Valve using 1.15 GPM @ 60 PSI
d. T&S B-7132-01. In lieu of standard, provide with B-0108-C
1.2 GPM spray valve @ 60 PSI.
2. Rear Feed Control Valve; 3" or 4" center to center remote
control valve with internal spring loaded checks; rear supply
and rear feed connections; lever handles;
a. Fisher model 2805-CV*M112
b. T&S model B-0513*M112 with Two (2) B-CVH-1/2 check
valves.