Specifications

ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-76
the features listed. Provide with the followings;
1. Additional Clamshell® Hood for model 148TH, (factory
installed) (CSE24)
2. Griddle/Clamshell Stand, 47-3/4"W x 25"D x 25-1/2"H, open
base w/undershelf, tubular legs w/casters, stainless steel
construction (ES-G48C)
3. Custom grooving, entire 48" top; (in increments of 12", NOTE:
max 24" grooving on left side & 24" on right side GROOVING)
4. Provide clam shells with master Power Switch(s) for CSE24
Hoods which will prevent hoods from automatically turning on
when lowered.
B. Secured to the floor beneath the rear casters and located to
properly position equipment below fire suppression nozzles,
provide Dormont model PS - Posi-Set mobile cooking equipment
locators; overall 9-3/4"L. x 4-1/4"W. x 1"H. Upward opening
channel shaped caster guide constructed of flame regardant
thermoplastic resin; able to resist 500 psi direct force; set
in sealant and secure to floor per manufacturers recommendations
with manufacturer provided floor inserts.
ITEM NO, C14 - WATER FILTER; COMBI
REQUIRED
A. Provide Selecto Scientific model SMF Steamer Guard Flash 5000
with SMF IC600 pre filter; system part: #81-6000; regeneration
cartridge: #108-068; Wall Mounted System: 15W. X 8"D X 28‖H.
Reduces lime scale build-Up; reduces calcium, alkalinity & bad
taste and odor; supply high quality, hardness free water; high
efficiency hydrogen resin technology; rated capacity for scale
& alkalinity - 5,000 gallons, total capacity: 87,700 Grains;
flow rate 1 - 5 gpm; 40 125 psi water pressure; 40º 100º
F operational temperature range; ½" barded Inlet/Outlet Size;
Tank: 10‖ Dia. X 38‖ Tall.
ITEM NO. D1 - SINK; 3 COMPARTMENT W/ SCRAP SINK
REQUIRED
A. Provide overall 2'-6"W. x 10'-0"L. x 34" high to work top.
Construct in accordance with standard specifications for Rolled