Specifications

ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-72
1. Electronic Timer with Load Compensating Feature, two
compartment (ETC2).
2. P/N 106174 Descaling Solution, (6) one-gallon containers with
quart markings (DISSOLVE)
3. P/N 107142 Boiler Descaling Pump Kit, for 15 psi boilers
(BDPK)
B. Provide with Two (2) Dormont model W75B2Q48*M112 Safety System
Hi-PSI® Water Connector Hose; 3/8" dia.; 48" long; covered with
stainless steel braid; brass two way quick disconnect on one end;
NPT male thread on one end; limited lifetime warranty.
C. Provide Kleensteam® II, Water Filter Assembly, for floor model
steamers, includes (1) CV cartridge, (1) AR-10 filter cartridge,
dip tube & ScaleKleen 2.2-lb packet, wall-mounting bracket &
gauge assembly (9797-21)
1. Provide with (5) additional AR-10 filter cartridges.
ITEM NO. C7 - KETTLE; ELECT 40 GAL TILT
ONE (1) REQUIRED - ONE (1) BY ALTERNATE
A. Provide Cleveland model KEL-40-TSH short series electric
tilting 40 gallon steam jacketed kettle; overall 45"W. X 39"D.
X 35"H. to the rim top. Self-contained; steam jacket filled
with treated water; accurate, consistent solid state
temperature controls - less than ±1C variance; operating
temperature range from 145 - 260F; controls include LED
indicator for heat cycle, LED indicator for low water, Power
ON/OFF switch, adjustable temperature control dial; water
resistant controls, splash-proof construction; large pouring
lip; re-inforced rolled rim; welded-in heating elements; kettle
and all exterior surfaces are of type 304 stainless steel with
an #4 finish; rear mounted easy access pressure gauge and
pressure relief valve; color coded easy to read pressure gauge
with "green" and "vent air zone"; 50 psi steam jacket rating;
50 psi safety valve; solid state water level control; splash
proof element cover with a double gasket seal; tilt mechanism
of roller bearings and case hardened self-locking worm and
segment gear; 1 5/8" O.D. tri-leg supports with level adjustable
feet for floor bolting; typical approvals include UL., CSA, CE,
NSF and ASME. Provide with the following options;