Specifications

ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-49
the following criteria as required:
1. Continuous equipment temperature monitoring and reporting
(-20F through 300F).
2. Temperature verification in the event of equipment failure.
3. Energy management adjustments (defrost cycles,
minimum/maximum temperature settings, average temperatures,
etc.).
4. Door openings/closing/time open.
5. Automatic alert notifications when temperature reaches
defined limits via numerous notification options.
6. Documentation of corrective actions taken (date, tie, action
taken and by whom).
7. Historical data retention in an electronic format-saved in
15 minute interval averages.
8. Automated database backups.
9. Easy report generation capability, for any time interval, on
any single piece(s) or group(s) of equipment, regardless of
location, that will be merged into a common report(s).
C. Temp Trak software is browser- based (Microsoft Internet
Explorer) and allows access to the management functions and
reporting features from any PC with network connectivity.
D. Provide the following Temp Trak Software and Hardware Products;
1. 1 ea Temp Trak Software Part No. 10400
2. 1 ea Base Station (w/ Buffer and LAN Converter Included) Part
No. 10000-5-P
3. 3 ea (for walk-ins Items A7, A8 and T1) Temperature Sensor
w/ Ext Thermistor-6‖ Probe (Cold 20F to 200F)Part No.
10080-115
4. 1 year limited warranty on all hardware included in
purchase price.
5. 1 ea Telephone Technical Support with High Speed Internet and
Remote Support Capability-5 Incident Call Pack Part No. 10711
6. Additional components as necessary relative to
installation / site conditions.
E. Owner provided equipment shall support the following;
1. Application Minimum Requirements (on an existing server or
an independent server)