Specifications

ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-36
H. Hinged Door(s) shall be 36" x 78". Construct door exterior with
22 ga. stainless steel, interior of same material as interior
walls. Doors shall be infitting flush type and with insulation
same thickness and material as wall sections. Fiberglass
Reinforced Plastic door perimeter, jamb and threshold. Heavy
duty cast alloy door handle and hinges with powder coat finish.
Three (3) positive action self-closing hinges with stainless
steel pin and nylon rising cam bearing. Door handle with key
lock and inside 1/4 turn safety release handle. Provide
thermoplastic gasket with magnetic core at door top and both
sides and adjustable sweep gasket at door bottom edge. Provide
heater wires around perimeter of door opening and door.
Factory-wire heater wires to J-box at door section. Hinge doors
as shown on plan.
1. Provide door with automatic door closer that firmly close
door to within 1 inch of full closure. Door shall self close.
Hinge door as shown.
2. Provide anti-sweat heater wires around perimeter of door
opening and door. Factory-wire heater wires to j-box at door
section.
a. If non-heat controlled antisweat heaters are used at entry
door, the total door rail, glass and frame heater shall draw
no more than 3.0 watts per square foot of door opening (for
coolers).
b. If heat controlled antisweat heaters are used at entry or
reach-in door(s), and the total door rail, glass, and frame
heater power draw is more than 3.0 watts per square foot
of door opening (for coolers), the antisweat heat controls
shall reduce the energy use of the antisweat heater in a
quantity corresponding to the relative humidity in the air
outside the door or to the condensation on the inner glass
pane.
3. When a concrete wear surface is shown poured atop walk-in box
floor panels, provide heated threshold flush in the finished
floor at entry door and extended height door frame(s) to allow
for concrete wear surface and threshold.
4. Provide with spring loaded, positively closing door hinges.
5. Provide 14 gauge stainless sill plate with non-skid
stripping, extend onto kitchen floor.
6. Provide door section with exterior, flush mounted, 4-1/2"