Specifications
ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-15
non-magnetic sheets, free of buckles, waves, and surface
imperfections. Provide No. 4 polished finish for any
surfaces exposed to view, 2B or 2D finish on unexposed
surfaces. Only in areas exposed to high temperature and high
acid/chloride exposure, type 316 Stainless Steel will be
used.
2. 304 Stainless Steel Tube: ASTM A 554, Type 304 with no. 4
polished finish.
3. Plastic Laminate: NEMA LD-3; horizontal exterior surfaces
with GP-50 (0.05" nominal) and vertical exterior surfaces
with VS-30 (0.03" nominal); interior surfaces white with 4
mil polyester; concealed surfaces with high pressure
balancing sheet.
4. Sound Deadening:
a. For all sound deadening applications; Component Hardware
Q75-2000 Multiflec Sound Deadener or equal, heavy-bodied
resinous coating, filled with granulated cork or other
resilient material, compounded for permanent, non-aging,
non-flaking adhesion to metal. Spray apply in 1/8" thick
coating and paint aluminum.
b. For Metal/Dish Table Tops only; Component Hardware Tack
Tape, or equal, sound deadening, tape form of sound
deadening applied between table reinforcing and metal top.
5. Sealant: Sealant shall be translucent Pecora Corporation 898
Silicone Sanitary Sealant, or other approved ASTM C 920, Type
S Grade NS, Class 25, use NT sealant which is an easily
cleanable CLEAR silicone sanitary sealant which does not
support bacterial growth, Shore A hardness of 30. Sealants
shall;
a. Be certified for compliance with NSF standards for use in
food service areas.
b. Washed and cured sealant shall comply with the FDA's
regulations for use in areas that come in contact with food.
6. Backer rods of closed-cell polyethylene rod stock of a size
larger than the joint width.
7. Elastomeric Joint Sealant:: ASTM C 920; Type S (single
component), Grade NS (nonsag), Class 25, Use NT (nontraffic)
related to exposure, and Use M, G, A, or O as applicable to
joint substrates indicated.