ACI/Frangkiser Hutchens Architects 4-07058
Liberty "North" Second High School
Liberty Public School District #53
Building Construction Bid Set
FOOD SERVICE EQUIPMENT 11400-118
section.
a. If non-heat controlled antisweat heater(s) are used at
entry or reach-in door(s), the total door rail, glass and
frame heater shall draw no more than 3.0 watts per square
foot of door opening (for coolers).
b. If heat controlled antisweat heater(s) are used at entry
or reach-in door(s), and the total door rail, glass, and
frame heater power draw is more than 3.0 watts per square
foot of door opening (for coolers), the antisweat heat
controls shall reduce the energy use of the antisweat
heater in a quantity corresponding to the relative humidity
in the air outside the door or to the condensation on the
inner glass pane.
3. When a concrete wear surface is shown poured atop walk-in box
floor panels, provide heated threshold flush in finished
floor at entry door and extended height door frame(s) to allow
for concrete wear surface and threshold.
4. Provide each door section with exterior, flush mounted,
4-1/2" diameter N.S.F. listed chrome plated dial thermometer.
5. Provide doors into non-refrigerated spaces with an interior
mounted thermo-plastic, insulating, slatted curtain.
6. Provide a window in the door. Minimum 14" x 14" window.
Refrigerator door(s ) window shall be double or triple pane
glass with heat-reflective treated glass or gas fill. Window
shall be field replaceable. Window centered at 60" aff.
7. Provide door with cylinder operation dead bolt lock with
reinforced installation in door and panel, safety release on
inside. Provide (5) keys.
8. Exposed-to-view exterior and interior of walk-in doors,
provide 36"H. wainscots constructed of .188 - 6061-T6 mill
finish aluminum tread plate and 3
rd
door hinge.
Mechanically secure tread plate to door and seal thereto.
9. As shown and required by Item T6, the Air Screen Merchandiser,
provide a buck opening in the front of the walk-in box.
I. Interior lighting;
1. On the exterior of the door section, adjacent to the door,
provide a light switch w/ pilot light. Light switch is
pre-wired to a junction box at the latch side upper corner
of the door opening; wiring in conduit concealed within the