Corp. Hot Beverage Maker Operation Manual
6
TROUBLESHOOTING GUIDE 
WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing 
any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical 
connections for proper contact. 
PROBLEM   PROBABLE CAUSE  REMEDY 
A  Dispensing unit unplugged  Reconnect dispensing unit 
B  No power from Terminal Block  Check the Terminal Block for loose wire 
C  Defective Bulb  Replace Bulb. 
D  Defective Ballast.  Replace Ballast. 
1 
Light Display 
not lit. 
No power. 
E  Loose Bulb in socket.  Make sure bulb is seated properly in socket. 
A  Water supply OFF.  Turn water ON. 
B  Clogged inlet screen (Water Inlet Valve).
Disconnect water line and clean inlet screen. 
C  Inoperative Water Inlet Valve.  Check connection, if needed replace Valve. 
2 
No water 
when Rinse 
Switch is ON. 
D  Loose electrical connection.  Check all electrical connections. 
A  No product in Hopper.  Add product. 
B  Auger not working.  Engage Hopper/Nut to Motor Gear (See section VI).
C  Damaged, loose, or missing Agitator 
Gear. 
Replace Agitator/Auger Gear (See section VI). 
D  Inoperative Auger Motor or Relay.  Check connections of Motor, Relay and/or Switch, 
if needed replace components. 
E  Hopper outlet clogged  Clean Hopper and check Cartridge Heater. 
3 
No product 
when 
Dispense 
Button is 
pressed 
F  Faulty Coupling.  Replace damaged Coupling components. 
A  Leaking Water Inlet Valve.  Clean/check fittings of Water Inlet Valve. Replace 
Water Inlet Valve if needed. See ”Water Inlet Valve 
Test” 
B  Inoperative Dispense Switch  Check Switch connections. 
Replace Dispense Switch if needed. 
C  Inoperative Rinse Switch  Check Rinse Switch connections. 
Replace Rinse Switch if inoperative. 
4 
Water does 
not shut off. 
Water keeps 
dispensing. 
D  Clogged/stuck Water Dispense Valve  Clean or unclog Water Dispense Valve. 
Replace Dispense Valve if inoperative. 
A  Heater Switch is OFF.  Turn Heater Switch ON. 
B  Thermostat is OFF.  Turn Thermostat ON. Turn Knob Clockwise. 
C  Loose connection on Thermostat.  Make sure all wires and terminals on Thermostat are
tight. 
D  Hi-Limit Temperature Switch is defective
Replace the Hi-limit. 
5 
Water is not 
heating up in 
the tank. 
E  Heater is burned out or defective.  Replace the Heater. 