Specifications

PROGRAMMING INSTRUCTIONS PROGRAM MODE
The a functional description of Version 1.07 of the dispensing controller is as follows:
Modes of Operation
1. Initializing Mode - This mode is only active during the first few seconds after a "power-on" or system reset. The
main function of this mode is to configure the system using the previously saved operating parameters.
2. Normal Mode - This mode becomes active immediately after Initializing Mode has completed its tasks. The main
functions of this mode are to monitor and report system status and control dispensing.
3. Rinse Mode - This mode becomes active when the Rinse key is depressed while in Normal Mode.
The main function of this mode is to allow the operator to initiate an individual Rinse for any enabled Hopper.
4. Program Mode -This mode becomes active when the Rinse and the Stop keys are simultaneously depressed for
more than 1.5 seconds while in Normal Mode. The main function of this mode is to provide limited access to
frequently used system parameters.
5. Service Mode -This mode becomes active when the hidden keys under the "Cecilware Logo" and the "Fast Flow
Logo" are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this
mode is to allow access to all system parameters that can be modified.
Initializing Mode
The following screen signifies this presence of this mode: CECILWARE
DISPENSER V#.##
It should be noted that this is the only time the System Software Version Number (V #.##) is displayed. All other
functions of this mode are completely transparent to the operator.
Normal Mode
The following is a list of functions performed by this mode:
1. Dispensing Control -This mode is responsible for implementing and supervising the dispensing process.
2. Water Level Control -This mode is responsible for maintaining the proper level of water in tha reservoir tank.
3. Water Temperature Control - This mode is responsible for maintaining the required water temperature in the reservoir
tank.
4. Sanitary (Rinse) Functions -This mode is responsible for annunciating and enforcing rinse warnings and lockouts.
5. Safety Functions -This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper
operation.
Rinse Mode
An individual Rinse is initiated by simultaneously pressing the Rinse key and a Dispense key corresponding to the
hopper to be rinsed.
9