Specifications
FE-100
Gas
SPECIFICATIONS
Dimensions
Body Depth 16"
Overall Depth
to faucet centers: 19 1/2"
Working Height 26"
Overall Height: 31"
Overall Width: 37 1/2"
Water Connection: 1/4" tubing
Constructed of type 304,
18-8 Stainless Steel
Approx Ship Wt; 125 Ibs.
Performance 15 gals. per hr.
Gas Data 32,000 BTU. Natural & Propane
Electrical Data 120V. 3 amps
plug-in for
electrical
accessories
Note: Use TOSSAWAY- PAPER FILTERS No. 718
INSTALLATION INSTRUCTIONS
FE-100G GAS AUTOMATIC
SPECIFICATIONS:
Natural Gas - 32,000 BTU @ 4" W.C. Pressure Electrical Connections — Cord Type Plug-in
Propane Gas- 32,000 BTU @ 10" W.C. Pressure 120 Vac, 15 Amp — 50/60 Hz
Power Requirement — 3A @ 120V 50/60 Hz
INSTALLATION:
CAUTION: Examine the gas specifications label attached to the urn to be certain that the type of I)JS for which the unit is equipped is the
same as the gas supply.
It is essential to leave a minimum clearance of 6" from the side walls and 8" from the rear wall.
Machine is supplied with a water strainer (23) and a 19" length of 1/4" (outside diameter) copper tubing with a flare fitting. Connect the copper
tubing with the flare fitting to the water connection at the rear of the machine. The other end of the strainer is connected with a suitable length
of '/4" tubing and shut off valve (supplied by a plumber) to a cold water supply. Water pressure should be a minimum of 20 Ibs. for proper
operation.
Before connecting the gas line, turn on the water supply valve and insert the line cord into a 120V grounded outlet. The water will start entering
the urn and the water filling operation will be going on while the gas connections are made, thus saving installation time.
Connect the 3/8" gas line to the gas shut-off valve (1) located at the rear of the thermostat control. Check all gas connections with soap solution
before attempting to light urn.
LIGHTING AND ADJUSTMENTS - (Refer to Illustration 1) Water must be visible in the gauge glass before lighting pilot.
Turn on the main gas valve and set the thermostat dial to the desired temperature. Turn the gas cock valve (9) on top of the thermostat to the
"pilot" position. Insert a lighted match through the opening located on the bottom of the urn and depress the pilot button (10) while lighting the
pilot. Hold down the pilot button for at least 30 seconds and release. The pilot will remain lit.
NOTE: It may be necessary on the first lighting to hold the pilot button for a longer period to allow the trapped air to escape from the lines. Turn
the gas cock valve (9) to the "ON" position and the burner will light.
2