User Guide
3.  Open the control box and disconnect the two pump wires from the 
quick disconnect terminals. 
4.  Loosen union fittings on pump and remove pump from urn. 
5.  Replace pump and follow priming instruction. 
NOTE: Pump and motor assembly is factory lubricated for the life of the 
pump. 
•  TIMER SOLID-STATE 
Depress BREW button, hold for approximately 10 seconds, and then 
release. If water flows from spray head when button is depressed and 
stops flowing after button is released, then timer is faulty and should be 
replaced. No water from spray head when button is depressed, indicates 
BREW button is fault and must be replaced. 
•  AGITATOR 
OPERATION: The agitator pump circuit is programmed to operate when 
the BREW button is pushed. Upon completion of the pump cycle, the 
agitator pump will pump air through the manifold into the coffee gauge 
glasses and into the coffee liner. The completed cycle will take 
approximately 20 second. The agitator may be operated independently 
of the brewing cycle, if the agitator button is depressed. 
MAITENANCE: The air pump is capable of delivering enough air for 
proper blending. However if enough agitation is not present, check 
flexible tubing on top of gauge glasses and fittings, for possible air leaks. 
If air pump does not operate on completion of brewing cycle or when 
agitation button is depressed, replace air pump or solid state agitator 
timer (black box). 
•  BURNER MAITENANCE 
The two main burners can be removed by first removing the base cover 
panel and unfastening the burner ends. The main burners should be 
cleaned both inside the venturi portion and on the outside using a soft 
bristle brush. The main burners must be into the same position before 
removal. Once a year, a qualified service agency should be contacted to 
inspect the appliance for safe and proper operation. 
IN
O
N
F
I
L
O
P
T
F
O
 PILOT ADJUSTMENT CAP
•  SAFETY PILOT: 
Remove pilot adjustment cap on 
the gas valve and turn adjustment 
screw to provide properly sized 
flame (3/4 inch long). 
Replace the cap. 
9