Specifications

PARTS LIST ME 10/15E
No. Description ME-10E ME-15E No. Description ME-10E ME-15E
1 Gauge Shield Mounting Bracket U160A U160A 20 Thermostat Bezel M016A M016A
2 Vent Cap Assembly K108A K108A 21 Control Box R484A R484A
3 Gauge Shield Washer KH X012A X012A 22A High-Limit Control 120V L224A L224A
4 Water Gauge Glass X030A X043A 22B High-Limit Control 240V M0602 M0602
5 Water Gauge Shield D020A D031A 23 Flange U013A U103A
6 Handle X007A X007A 24 Heater Gasket M0680 M0680
7 Plastic Bonnet X010A X010A 25A Heater 120V G199A G199A
8 Faucet Spring, S.S. X019A X019A 25B Heater 240V G197A G197A
9 Stem X058A X058A 26 Control Box Cover R485A R485A
10 Cup Seat X014A X014A 27 Thermostat L029A L029A
11 Silicon Gasket M256A M256A 28 Terminal Block BOOOA BOOOA
12 Faucet Assembly 0017A D017A 29 Overflow Tube H084Q H059Q
13 Shank D021A D021A 30 Vent Cap Drain U019A U019A
14 Dial Thermometer L007A L007A 34 Stem Valve M0251 M0251
15 Chrome Plated Nut, %" NPT K110A K110A 35 Adapter, % - 20 M0589 M0589
16 Body R479A R480A 36 S.S. Float, 3" M0892 M0892
17 Legs,set of 4 M005S M005S
37 Knob M027A M027A
18 Overflow Drain E071A E071A 38 Cover Q102H Q102H
19 Thermostat Knob M008A M008A
ME 10E / 15E WATER BOILER
Wiring diagrams
Schematic
diagrams
Electrical data
CONVERSION INSTRUCTIONS FOR ME-10E and ME-15E WATER BOILERS
Conversion from 208 volts or 240 volts to 120 volts
To convert to 120 volt 15 amp outlet application simply connect a 120 volt 15 amp line cord equipped with 2 prong grounding cap to
terminal as follows.
1. Connect white lead to terminal block marked (L1).
2. Connect black lead to terminal block marked (L2).
3. Connect green lead to copper ground terminal marked GND.
4. Secure cord to terminal box with a strain relief clamp.
5. Change Marketings on Rating Label to reflect the voltage change.
8
ME
10E/15E
120V
208/240 V/1 phase
VOLTS: 208/240
50/60 HZ
WATTS: 5300/7000
AMPS: 25.5/29.2
PHASE: 1
120 Volt Hook Up
VOLTS: 120
50/60 HZ
WATTS: 1750
AMPS: 14.6
PHASE: 1