ERROR MODE 
Description – The main function of Error Mode is report any system malfunctions and to disable the 
unit The system must be “powered down” using the Power Key located on the membrane keypad 
to reset any reported error. 
KEYPAD  ! SYSTEM ERROR ! 
KEYPAD 
Description – This screen is displayed and the unit is disabled when a key-press is detected during 
the initial application of power to the system. This test is not performed during a Power Key 
initiated “power-on” sequence. 
Possible Causes – Membrane Keypad or someone depressing a key while applying power to the 
system 
110/220VAC ON  ! SYSTEM ERROR ! 
110/220VAC ON 
Description – This screen is displayed and the unit is disabled when line voltage is detected before 
the Safety Relay is energized. 
Possible Causes – Wiring or Safety Relay 
110/220VAC OFF  ! SYSTEM ERROR ! 
110/220VAC OFF 
Description – This screen is displayed and the unit is disabled when line voltage is not detected 
after the Safety Relay is energized. 
Possible Causes – Wiring, Fuse, High Temp Limit Switch, Control Board or Safety Relay 
HIGH WATER TEMP  ! SYSTEM ERROR ! 
HIGH WATER TEMP 
Description – This screen is displayed and the unit is disabled when the present water temperature 
is sensed as being higher than 208 °F.
Possible Causes – Wiring, Power Triac, Control Board or Water Temperature Sensor. 
OVER FLOW  ! SYSTEM ERROR ! 
OVER FLOW 
Description – This screen is displayed and the unit is disabled when the Over Flow Level Sensor is 
detecting the presence of water. 
Possible Causes – Wiring, Fill Solenoid, Control Board or Level Sensor 
NO FILL RESPONSE  ! SYSTEM ERROR ! 
NO FILL RESPONSE 
Description – This screen is displayed and the unit is disabled when the Fill Solenoid has been 
continuously energized (open & filling) for more than 15 minutes during the first fill or more than 30 
seconds thereafter. 
Possible Causes – Water Supply is turned off, Wiring, Control Board, Fill Solenoid or Level Sensor 
NO TEMP RESPONSE  ! SYSTEM ERROR ! 
NO TEMP RESPONSE 
Description – This screen is displayed and the unit is disabled when the Water Heater has been 
continuously energized (heating) for more than 45 minutes. 
Possible Causes – Wiring, Control Board, Water Temperature Sensor, Power Triac, or Water Heater 
DUMP #1 CLOSED  ! SYSTEM ERROR ! 
DUMP #1 CLOSED 
Description – This screen is displayed and the unit is disabled when the system has been brewing 
(dispensing) for more than one minute and the Level Sensor has not sensed the absence of water. 
Possible Causes – Wiring, Control Board, or Dump Solenoid. 
TEMP SENSOR  ! SYSTEM ERROR ! 
TEMP SENSOR 
Description – This screen is displayed and the system is shut down when the Water Temperature 
Sensor is detecting an invalid (below 32°F or above 220°F) water temperature. 
Possible Causes – Wiring, Control Board or Temperature Sensor. 