Specifications

9
SOAK TIME SOAK TIME
## SECONDS
Description – The Soak Time is the amount of time that the system will wait between the end of the hot water
infusion period and the beginning of brewing.
PULSE BREW PULSE BREW
ON/OFF
Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing (pulsing)
hot water.
PULSE ON TIME PULSE ON TIME
## SECONDS
Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot water
during a Brew Cycle.
PULSE OFF TIME PULSE OFF TIME
## SECONDS
Description – The Pulse OFF Time is the amount of time that the system will wait between hot water dispenses
during a Brew Cycle.
DRIP TIME
DRIP TIME
### SECONDS
Description – The Drip Time is the amount of time that the system will wait after the completion of the hot water
dispense before signaling the end of the Brew Cycle. This allows time for any water remaining in the funnel to
drain out.
DILUTION DILUTION (36)
ON/OFF
Description – The Dilution feature gives the user the ability to add hot water directly to the brew without passing
through the grinds. This option is only available in models with a 36-Cup Dispense Key.
DILUTION PERCENT DILUTION PERCENT
## %
Description – The Dilution Percent is the percentage of the total volume of the brew (Brew Size) that is diluted
DILUTION FILL CONSTANT DIL FILL CONST
#.## OZ/SEC
Description – The Dilution Fill Constant is the exact value of the rate at which hot water is dispensed from the
Dilution Solenoid Valve during each Brew Cycle. The accuracy of this value is crucial to the proper operation of
this system. This value is directly related to the orifice size of the Dilution Solenoid Valve. A simple method for
calibrating the Dilution Solenoid Valve has been provided in Normal Mode (see Dilution Fill Constant Calibration
section of Normal Mode Descriptions).
DILUTION DELAY DILUTION DELAY
### SECONDS
Description – The Dilution Delay is the amount of time the system waits from the start of Brewing to the start of
Dilution.
WATER TEMPERATURE WATER TEMP
### °F
Description – The Water Temperature is the required (set point) temperature of the water in the reservoir tank.
TEMPERATURE SENSOR CALIBRATION TEMP SENSOR CAL
ARE YOU SURE ?
Description – The Temperature Sensor Calibration allows the user to offset (calibrate) the displayed water
temperature to a reference thermometer.
Instructions – Use the [Arrow] Keys to adjust (calibrate) the displayed
temperature to match the reference thermometer. Depress one of the
[Hidden] Keys when the calibration is complete.
TEMP SENSOR CAL
### °F
LOCKOUT TEMPERATURE LOCKOUT TEMP
### °F
Description – The Lockout Temperature is the minimum brewing temperature. The system will not allow a Brew
Cycle to begin unless the water is above the Lockout Temperature.