Specifications

6
MODES OF OPERATION – DESCRIPTIONS
Initialization Mode:
The following screen signifies the presence of this mode:
CECILWARE
&&&&& REV #.#
Description – This mode is active only during the first few seconds after “power-on”. The purpose of the
Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number
(depicted by “#.#”).
Normal Mode:
The following screen signifies the presence of Normal Mode:
SSSSSS DDD K
SSSSSS HH:MMP
Description – Normal Mode is active immediately after Initialization Mode. The left half of the screen
displays the present System State (depicted by “S”). Refer to the subsequent State Descriptions in this
section for more information on System States. The right half of the screen displays the present day of the
week (depicted by “D”), the present time (depicted by “HH”:”MMP”), and the current Key Lock Status
(depicted by “K”). The day of the week is identified using familiar three letter abbreviations. The time is
identified using hours and minutes along with a “AM/PM” indicator. If KeyLock is enabled the” KL” symbol
will be present. Enabling KeyLock will prevent unauthorized users from operating the unit. Refer to the
Service Mode Descriptions for more information on the KeyLock function.
Filling State
FILLING DDD K
TANK HH:MMP
Description – This screen is displayed during the initial filling of the water tank (first fill). Once the water in
the reservoir tank has reached the appropriate fill level this screen is retired.
Heating State:
HEATING DDD K
TTTF HH:MMP
Description – This screen is displayed when the present water temperature is below the Lockout
Temperature Set Point. The actual water temperature is displayed in the lower left-hand portion of the screen
(depicted by “TTTF”). If the Brew Key is depressed while in the Heating State the system will advance to the
Waiting State. If the Brew Key is depressed for more that three seconds the Waiting State is bypassed and
the system will advance to the Brewing State.
Waiting State
WAITING DDD K
TTTF HH:MMP
Description – This screen is displayed when the operator presses the Brew Key while the system is in the
Heating State. The actual water temperature is displayed in the lower left-hand portion of the screen
(depicted by “TTTF”). The Brew Key LED will blink in this state. Once the water temperature reaches the
Lockout Temperature Set Point the system will automatically advance to the Brewing State.
Pressing the Brew Key or the Cancel Key while in the Waiting State will cause the system to revert back to
the Heating State.
Ready (to Brew) State
READY DDD K
TO BREW HH:MMP
Description – This screen is displayed when the system is ready to begin a Brew Cycle. Pressing the Brew
Key while in the Ready State will advance the system to the Brewing State (i.e. begin a Brew Cycle).
Brewing State
BREWING DDD K
MM:SS HH:MMP
Description – This screen is displayed when a Brew Cycle is in progress. The time remaining in the Brew
Cycle is displayed in the lower left-hand corner of the screen (depicted as “MM:SS”). The Brew Key LED will
blink in this state. The Main Warmer is automatically activated upon entry into this state. The Brewing
parameters of Brew Size, Dilution, Pre-Infusion, Pulse Brew, and Drip Time are utilized in this state. Refer to
the Service Mode Descriptions for more information on Brew parameters.
Pressing the Brew Key or the Cancel Key while in the Brewing State will abort the Brew Cycle and revert the
system to the Ready State.
Brew Fill Constant Calibration State
--