Specifications

PROBLEM PROBABLE CAUSE REMEDY
1
Brewed Cold Tea.
a) Heater Switch OFF.
b) Run out of hot water
c) Thermostat is OFF.
d) Loose electrical connection.
e) Thermostat is defective.
f) Hi-Limit Temperature Switch is tripped.
g) Bad Heating Element or Heater is burned out.
h) Bad low temperature cutout circuit.
Contactor/Relay L538A
a) Turn Heater Switch ON.
b) Allow time for water in tank to heat after filling.
c) Set Thermostat at 197°F [to max. position].
d) Check all electrical connections for contact.
e) Replace Thermostat.
f) Reset the Hi-Limit button, If heater still does not work, replace
the Hi-limit Temperature Switch. See Item 6 of Tank Ass’y.
g) Replace Heater.
h) Replace Contactor/Relay. See item 2 of Description of Components.
2
Tea too weak.
a) Not enough Tea in the funnel insert.
b) Water flow too low.
c) Brew time is too short.
d) Water is too cold.
a) Put more Tea in the funnel insert [see Lipton’s chart]
b) Check flow [should be .26 gal /min.] Replace Dispense Valve.
c) Adjust hot water timer to 3 min. max.
d) Adjust Thermostat to 197°F [to max. position]
3
Tea too strong.
a) Too much tea in the funnel.
b) Water flow is high
c) Brew time is too long.
d) Water is too hot.
a) Put less Tea in the funnel insert [see Lipton’s chart]
b) Check flow [should be .26 gal /min.] Replace Dispense Valve.
c) Adjust hot water timer to 3 min. 197°F [to max. position]
d) Adjust Thermostat to 197°F [to max. position]
4
Water keeps dripping
or running from
dilution nozzle.
a) Leaking Water Inlet Valve.
b) Clogged/stuck Water Dispense Valve
a) Clean/check fittings of Water Inlet Valve.
Replace Water Inlet Valve if needed. See ”Water Inlet Valve Test”
b) Clean/unclog Water Dispense Valve.
Replace Dispense Valve if defective.
5
No water is going
into tank at all.
or
No water is coming
from dilution nozzle
a) Water Inlet Valve malfunction.
b) Hi-Level Float Switch malfunction.
c) Probe malfunction.
d) Solid State Water Level Controls board
malfunction.
e) Timer malfunction.
a) Check Water Inlet Valve. Replace if necessary.
See “Water Inlet Valve Test”
b) Test High-Level Float Switch. See “High-Level Float Test”
c) Check Probe. Replace if necessary.
d) Check The Water Level Controls. Replace if necessary.
e) Check Timer: Time dispinsing time vs. set time on Timer.
Replace if necessary.
6
Water will not stop
flowing into water
tank.
a) Water Level Probe malfunction.
b) Solenoid (Water Inlet Valve) malfunction.
c) Solid State Water Level Control board
malfunction.
d) Float Switch malfunction.
a) Check Level Control Probe. Replace if necessary. See “ProbeTest”.
b) Check Solenoid. Replace if necessary.
c) Check The Water Level Controls. Replace if necessary.
d) Replace Float Switch.
7
Water is not heating
up in the water tank.
a) Heater Switch is OFF.
b) Thermostat is OFF.
c)Loose connection on Thermostat.
d) Hi-Limit Temperature Switch is tripped
or defetive.
e)Heater is burned out or defective.
h) Bad Low Temperature Cutout Circuit.
Contactor/Relay L538A.
a) Turn Heater Switch ON.
b) Turn Thermostat ON. Turn Thermostat Knob Clockwise.
c) Make sure all wires and ring terminals on theThermostat are tight.
d) Reset the Hi-Limit Button, If heater still does notwork,
replace the Hi-limit Temperature Switch (see Item 6 in Tank ill.).
e) Replace the Heater.
h) Replace Contactor/Relay. See item 2 of Description of Components.
TROUBLESHOOTING GUIDE