4. PROGRAMMABLE TIMER "TEACH ME" L576A ADJUSTMENTS - LTB-1010 :
This timer can be programmed from the brew button to dispense different volume of hot water.
PRIMING:
a. Make sure heater switch is off.
b. Push & hold down brew button while switching power on .
c. Release brew button.
d. Push brew button again & wait for water to start flowing out of spray head.
e. Switch power off.
Put timer into program mode:
a. Start with power off.
b. While holding down brew button, turn power on.
c. Release dispense button.
Program the brew button :
d. Push brew button to start time [product begins dispensing].
e. Push brew button again to stop time
[about 2" from top of dispenser for 10 gal.] [product stops dispensing] .
f. Brew button can be jogged to top off container.
Put timer into run mode:
g. Turn power off and on again [this locks in total dispense time].
Normal Operation: turn power on, turn heater switch on,
wait 20 minutes until ready light comes on. Unit is ready to brew.
5. DUAL WATER INLET VALVE CD241 [WAS L496A]:
The Water Inlet Valve is located on the lower part of the main body with
the threaded end protruding out of in the back.
The Water Inlet Valve allows water flow up to .87 gal./min. [gpm].
One side supplies water to the tank and one side supplies water directly
to the Iced Tea dilution water nozzle. The time that each side draws
water is controlled by the Hot Water timer and Cold Water Timer.
6. DISPENSE VALVE L467A :
Locate Dispense Valve, by removing the top lid of machine.
Looking down into the machine, the Dispense Valve is mounted on the tank.
FIXED FLOW: 1 LITER/MINUTE [0.26 gal./ minute]
LTB-303 3 liters in 3 minutes [0.78 gal. in 3 minutes]
LTB-505 5 liters in 5 minutes [1.3 gal. in 5 minutes]
LTB-1010 10 liters in 10 minutes [2.6 gal. in 10 minutes]
7. THERMOSTAT ADJUSTMENT L681A (WAS L002A or L626A):
Locate Thermostat: Remove the top cover. Thermostat is mounted on top of tank.
The thermostat is factory set to deliver hot brewing water at 195°F with the thermostat
knob turned to full ON position. If adjustments should be necessary to increase or
decrease the water TEMPERATURE, proceed as follows:
To INCREASE the water temperature,
Turn Thermostat Shaft to its maximum clockwise, CW, position.
Remove the knob and locate the Slotted Adjustment Screw inside
the hollow thermostat shaft. Using a narrow-bladed screwdriver,
engage slotted adjustment screw and turn it ¼ turn slowly counterclockwise, CCW .
Allow a few minutes for the temperature to reach set level. The Heater Light will go ON,
indicating the heating element is activated, wait for it to go OFF, indicating that the water
has reached new set temperature. Take a temperature reading and repeat if necessary.
To DECREASE the water temperature - simply turn the Thermostat Knob one notch
counterclockwise CCW to the next lower dial setting.
14