Specifications

13
ADJUSTMENTS - TO BE PERFORMED BY QUALIFIED SERVICE PERSONNEL ONLY.
Caution:
Brewers should be unplugged from electrical outlets before any service is performed.
The water flow rate coming from the hot water tank is constant/fixed at 0.75 gal/min.
Increasing or decreasing the amount of hot water dispensed from tank can also be used to adjust the strength of
the tea.
The Longer water flows - More water - Weaker tea; Less water flows - Less water - Stronger tea.
The LTB-303, 505, 103, 105, 1010 Machine will complete a full cycle in approximately 5 TO 10 min.
1. HOT WATER TIMER (BLACK L265A) ADJUSTMENT (MOUNTED ON TOP)
Controls the brewing time (min.) for brewing Coffee and Hot Tea Concentrate
Factory set at 3 min. for brewing 3 liters [3/4 gal.] of Tea Concentrate.
[later to be diluted with 2 1/4 gal. of cold water which makes up the
total 3 gal. Iced tea] .
To increase or decrease dispensing time and volume of hot
water dispensed, turn knob in the direction shown on timer.
Note: The brewing time, temperature, and amount of product used in the funnel
effects the drink strength. See chart of Tea Flavors and Grams to be used, supplied by Lipton.
2. COLD WATER TIMER (BLUE L264A) ADJUSTMENT (LTB-303, 505 ONLY)
(MOUNTED ON TOP).
Controls the dispensing time (min.) for cold water dilution of iced tea.
Factory set at 3 min. for dispensing 2 1/4 gal of cold water -
dispensed & mixed with 3 liters [3/4 gal.] of hot tea concentrate previously brewed .
To increase or decrease dispensing time and volume of Iced Tea dilution water
dispensed, turn knob in the direction shown on timer.
TO RESET TO FACTORY SETTINGS:
*Push the Brew Button (HOT TEA) , then adjust Timer to 3 or 5 min. [for 3 or 5 gal.] depending on the
water pressure in the main water line.
*Adjust the Dispense Valve 1/4 turn at a time, if necessary, to increase or decrease the Hot Water Flow.
*Push the Brew Button (ICED TEA) , then adjust the Timer to 3 min. or 5 min. [for 3 or 5 gal.] depending
on the water pressure in the main water line.
3. DELAY TIMER (L595A) [ALL LTB UNITS] -NEAR BASE, ABOVE WATER INLET VALVE.
(MOUNTED IN BACK)
Set Delay Timer knob approximately as shown in picture. This setting corresponds
to a delay time of 1.5 minutes after the hot tea begins to dispense.
If the water pressure requires a different setting on the Cold Water Timer,
then the Delay Timer also needs to be adjusted so that it delays the Cold Water
1.5 minutes after the hot tea begins to dispense.
If the water pressure is higher than 20 PSI , decrease the setting on the Cold Water Timer and Delay Timer.
If the water pressure is lower than 20 PSI , increase only the setting on the Cold Water Timer to Max.
APPROX. FACTORY SETTING:
LTB-303/103 3 MIN.
LTB-505/105 5 MIN.
APPROX. FACTORY SETTING:
LTB-303 3 MIN.
LTB-505 5 MIN.
13